ecobee Smart Premium Thermostat
WELCOME!
If you have questions, we have answers.
Visit ecobee.com/support for tutorials, how-to videos and FAQs. Technical support is also available by email or by phone:
support@ecobee.com
1-866-518-6740
COMPATIBLE SYSTEMS
Smart Thermostat Premium works with most centralized residential heating and cooling systems.
- Heating: Up to 2 stages
- Cooling: Up to 2 stages
- Heat pumps: Air, Water, and Geothermal with up to 2 stages, and 2 stages of AUX heat. Accessories: Dehumidifier, humidifier, or ventilation device.
- Fan coil units: 2- and 4-Pipe with up to 3 fan speeds. Pipe sensors supported.
- Packaged Terminal Air Conditioners (PTAC): Up to 3 fan speeds
IMPORTANT — TURN OFF POWER
Power off the HVAC system with the master switch or circuit breaker box.
WARNING! ecobee Smart Thermostat Premium is designed for 24VAC with a 2A maximum current. Do not connect it to line (high) voltage or millivolt systems.
TERMINAL DESCRIPTIONS
- G Fan
- Rc Cool transformer
- Rh Heat transformer
- O/B Heat pump reversing valve
- Y1, Y2 Used for 1-2 stages of conventional A/C or 1-2 stages of heat pump compressor
- W1, W2 Used for 1-2 stages of conventional heat or 1-2 stages of auxiliary heat with heat pump
- C 24VAC common
- ACC+/– Used for dehumidifiers, humidifiers, ventilators, HRVs or ERVs
- PEK+ Power Extender Kit (PEK), which extends a C-wire when a physical wire is not available. PEK sold separately for Pro Builder models.
CONVENTIONAL HEATING AND COOLING
(UP TO 2 STAGES EACH)
CONVENTIONAL HEATING AND COOLING
(WITH PEK)
NOTES:
- When using a PEK with a heat pump system, the O/B terminal is wired directly to the thermostat.
- The PEK is not compatible with dual transformer or fan coil units.
HEAT PUMP (AIR OR GEOTHERMAL)
WITH AUXILIARY HEAT
NOTE: Heat pumps use an internet-based weather feed and do not require outdoor temp sensor and/or a dual-fuel kit.
PACKAGED TERMINAL AIR CONDITIONER
(PTAC) WITH MULTISPEED FAN
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
1-WIRE ACCESSORY
NOTE: Self-powered 24V accessories can be controlled using the ACC+ and ACC− terminals.
2-PIPE FAN COIL UNIT WITH AUX HEAT
(PIPE SENSORS OPTIONAL)
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
4-PIPE FAN COIL UNIT
NOTE: G1, G2, G3 may also be labeled as GL, GM, GH
BOILER OR RADIANT SYSTEM
Installation Settings
THRESHOLD SETTINGS
Menu > Settings > Installation Settings > Thresholds
SETTING NAME | DESCRIPTION | DEFAULT |
Conventional & Heatpump Systems | ||
Auto Heat/Cool | In Auto mode, the thermostat will engage both your heating and cooling as necessary. | Enabled |
Heat/Cool Min Delta | The minimum temperature difference between the desired Heat and Cool set points in Auto mode. | 5F |
Configure Staging |
Configure staging Manually, to select and customize values such as dissipation time, temperature deltas, and runtimes for both your heating and cooling equipment. (See *Manual Setting Options) |
Automatic |
Compressor Min Cycle Off Time | The amount of time the compressor remains off between cycles. | 300 seconds |
Compressor Min Outdoor Temperature |
The AC or Heatpump compressor will not run below this outdoor temperature. |
AC – 35F /
Heatpump – User defined |
AC Overcool Max | Will allow the air conditioner to overcool (above Cool set point) by this value to help decrease humidity. | Disabled |
Heat Min On Time | The minimum amount of time the furnace/boiler will stay on during a call for heat. | 5 minutes |
Compressor Min On Time | The minimum amount of time the compressor will stay on. | 5 minutes |
Temperature Correction | If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. | +0F |
Humidity Correction | If the thermostat sensor reading is incorrect, a correction may be applied to achieve an accurate reading. | +0% |
Thermal Protect | The minimum temperature reading difference between sensors that will trigger the algorithm to ignore the inaccurate sensor reading. | Disabled |
Installer Code | When enabled, this restricts access to Installation Settings (Code 3262 permits access) | Disabled |
Heatpump only Systems | ||
Aux Savings Optimization | This setting simplifies Heatpump to Aux Heating staging based on Savings vs. Comfort. The higher the temperature setting will sacrifice comfort for savings. | 2F |
Aux Heat Max Outdoor Temperature | The Auxiliary Heat will not run above this outdoor temperature. | 35F |
Aux Min On Time | The minimum amount of time your auxiliary heat will stay on during a call for aux heat. | 5 minutes |
Compressor To Aux Temperature Delta | The minimum number of degrees from the current temperature vs. set point before engaging the auxiliary heat. | Auto |
Compressor to Aux Runtime | The minimum number of minutes the Heatpump compressor will run for before switching to auxiliary heat. | Auto |
Aux Reverse Staging | When enabled, aux heat will be engaged if the current temperature is greater than the value designated in the Compressor to Aux Temperature Delta setting. | Off |
*Manual Setting Options | ||
Heat Differential Temperature | The minimum temperature differential before engaging heating. | 0.5F |
Heat Dissipation Time | The amount of time the fan will continue to run once the heating cycle is completed. | Auto |
Cool Differential Temperature | The minimum temperature differential before engaging cooling. | Auto |
Cool Dissipation Time | The amount of time the fan will continue to run once the cooling cycle is completed. | Auto |
Compressor Reverse Staging | When enabled, second stage compressor will be engaged if the current temperature is greater than the value designated in the Compressor Stage 2 Temperature Delta setting. | Off |
Compressor Stage 2 Temperature Delta | The minimum number of degrees from the current temperature vs. set point before engaging the second stage of the compressor. | Auto |
Compressor Stage 1 Max Runtime | The maximum number of minutes running stage 1 before engaging the second stage of the compressor. | Auto |
Heat Reverse Staging | When enabled, second stage heat will be engaged if the current temperature is greater than the value designated in the Heat Stage 2 Temp Delta setting. | Off |
Heat Stage 2 Temp Delta | The minimum number of degrees from desired setpoint before engaging the 2nd stage of heat. | Auto |
Heat Stage 1 Max Runtime | The maximum number of minutes running stage 1 before engaging the second stage heating. | Auto |
ACCESSORY SETTINGS
SETTING NAME | DESCRIPTION | DEFAULT |
Humidifier | ||
Evaporative or Steam | An ‘Evaporative’ humidifier will operate with a heating cycle where an ‘Steam’ humidifier can operate with/without a heating cycle. | User defined |
Min Runtime Delta | The humidifier will run beyond the desired humidity setpoint by the selected amount | 5% |
Window Efficiency | The Frost Control setting uses the efficiency rating to determine the desired humidity within the range of 15 to 50%. | 2 |
Dehumidifier | ||
Dehumidify with Fan | When enabled, this will activate the furnace/air-handler fan during a call for Dehumidification. | Yes |
Min Runtime Delta | The dehumidifier will run beyond the desired humidity setpoint by the selected amount | 5% |
Dehumidify in Heat Mode | Will permit the Dehumidifier to operate independent of a heating cycle. | No |
Dehumidifier Active | This setting is dependent whether the HVAC system or Dehumidifier requires it to be open or closed while active. | User defined |
Ventilator | ||
Pre-Occupancy Purge | Enable to run ventilator for 1 hour prior to expected occupancy | Disabled |
Free Cooling Max Outdoor Temperature | Free Cooling will not run when the outdoor temperature is above this point | 72F |
Free Cooling Max Outdoor Temperature | Maximum Outdoor Humidity to permit Free Cooling to run | Disabled |
Indoor/Outdoor Temperature Delta | Permit Free Cooling if Indoor Temp vs. Outdoor Temp is greater than Temperature Delta | 2F |
Max Desired Temperature Delta | Maximum delta between current and desired temperature to engage Free Cooling | Disabled |
Pre-Occupancy Purge | Enable to run ventilator for 1 hour prior to expected occupancy | Disabled |
REMINDERS & ALERTS SETTINGS
SETTING NAME | DESCRIPTION | DEFAULT |
HVAC Maintenance | Maintenance interval for the heating & cooling systems. | Enabled, 6 months |
Furnace Filter | The frequency of filter reminders based on months or runtime hours. | Enabled, 3 months |
UV Lamp | The frequency when maintenance is needed based on months or runtime hours. | Disabled |
Low Temp Alert | When indoor temperature meets/exceeds this setting an alert will be generated. | Enabled, 50F |
High Temp Alert | When indoor temperature meets/exceeds this setting an alert will be generated. | Enabled, 92F |
Aux Outdoor Temp Alert | An alert will be generated when Aux Heat is used at this value or above. | Disabled |
Aux Heat Runtime Alert | An alert will be generated when Aux Heat meets/exceeds this runtime value in a 24hr period. | Disabled |
Low Humidity Alert | An alert will be generated if humidity falls below this value. | Disabled |
High Humidity Alert | An alert will be generated if humidity rises above this value. | Disabled |
Display Alerts on Thermostat | When enabled, Alerts will also appear on the thermostat display. | Disabled |
Enable Heating/Cooling Alerts | An alert will be generated indicating that the system has failed to heat or cool the indoor location. | Enabled |
Reference
Download manual: ecobee Smart Premium Thermostat User Guide