Introduction

The iT500 controls your heating and hot water from anywhere via your smartphone or laptop. Your pc and laptop connects to the system using existing broadband connection. The system is wireless so it’s easy to instal.

FEATURES:

  • Access and control your heating and hot water via the internet
  • Compatible with your PC or smartphone – they connect to the system using your existing broadband connection
  • Touch sensor panel
  • The internal system uses 868 MHz for robust communication
  • 3 system configurations:
    • One central heating zone only
    • Two central heating zones (optional iT300 remote sensor required for second zone)
    • One central heating zone plus hot water
  • ECO & HOLIDAY mode
  • Free iT500 Plus app to download

Box contains:

  • iT500TR thermostat
  • iT500RX receiver (a wireless receiver that will connect to your boiler.
  • It is suitable for combination and system boiler).
  • iTG500 Internet gateway – connects via a short cable to your broadband internet router.
    The gateway enables internet access and control of your system.

Product compliance

This product complies with the following EU Directives: Electromagnetic Compatibility 2014/30/EU, Low Voltage Directive 2014/35/EU, Directive 2014/53/EU and 2011/65/EU. Full information is available on the website www.saluslegal.com

Safety information 
Use in accordance with national and EU regulations. Use the device only as intended, keeping it in a dry condition. The product is for indoor use only. Installation must be carried out by a qualified person in accordance with national and EU regulations.

Technical specification

  • Supply:
    • iT500 – 2 x AA Batteries
    • iT300 – 2 x AAA Batteries
    • iT500RX – 230 V AC 50Hz
  • Rating Max:
    • CH1: 16 A resistive, 5 A inductive
    • CH2: 5 A resistive, 3 A inductive
  • Temperature range: 5°C – 35°C (in step 0,5°C)
  • Frost protection temperature: 5°C – 9°C (in step 0,5°C)
  • Hysteresis: 1°C
  • Storage temperature: -20°C to 60°C
  • Protection degree IP: IP 30

Connecting the gateway to your existing routersalus-it500-internet-thermostat-fig-1

Inserting the batteries in the iT500 Thermostat

  1. Remove the battery cover from the base of the iT500 Thermostat.
  2. Make a note of the serial number printed inside the base of the iT500 Thermostat.
  3. With the unit face down, insert the first battery supplied into the right hand side of the base of the iT500 Thermostat.salus-it500-internet-thermostat-fig-2
    Note: You can make a note of your STA number here for future reference:salus-it500-internet-thermostat-fig-3
  4. Insert the second battery supplied into the left hand side of the base of the iT500 Thermostat.
  5. Ensure the batteries are fitted securely in the base of the iT500 Thermostat.
  6. Replace the battery cover to the base of the iT500 Thermostat.salus-it500-internet-thermostat-fig-4

iT500 Plus application

Download the iT500 Plus app, create an account and register your device. Follow the on screen instructions to complete all the steps.

Features available only on the App:

  • HOLIDAY mode
  • Antifrost temperature changing
  • Energy saving mode (set the lowest schedule temp.)
  • Simplified schedule setup
    Note: You can add a few iT500 thermostat to one account.salus-it500-internet-thermostat-fig-5salus-it500-internet-thermostat-fig-6

LCD icon descriptionsalus-it500-internet-thermostat-fig-7

  1. Settings indicator
  2. Internet indicator
  3. RF signal indicator
  4. Low battery status
  5. Holiday indicator
  6. Button lock indicator
  7. Temperature unit
  8. Temperature indicator
  9. Hot water heating in continuous mode
  10. Hot water override
  11. Automatic mode
  12. Antifrost mode
  13. Hot water heating
  14. Hot water indicator
  15. Cooling mode indicator (zone 2)
  16. Zone 2 indicator
  17. Heat mode indicator (zone 2)
  18. Cooling mode indicator (zone 1)
  19. Zone 1 indicator
  20. Heat mode indicator (zone 1)
  21. Program number indicator
  22. Clock display
  23. Day of the week

Button functionssalus-it500-internet-thermostat-fig-8

Installation of wall bracket docking (optional)
For best results mount iT500 1.5m from ground level.

  1. Attach the wall mounting bracket to a suitable wall using the fittings supplied and the built in level.
  2. After first ensuring that the bracket is secure, clip the iT500 into place by aligning the recess on the back of the unit to the bracket and clipping into place.
  3. Once clipped into place, ensure the unit is securely seated on the bracket.

salus-it500-internet-thermostat-fig-9

Desk mount option iT500 
For the desk mounted option, simply clip the clear stand supplied separately into the back of the unit.

iT500RX receiver switch functionssalus-it500-internet-thermostat-fig-10

  1. AUTO – receiver operate in automatic mode (works according to thermostat or app)
  2. MANUAL – receiver operate according to the switch located below
  3. OFF – receiver is disabled
  4. CH – in manual mode, zone 1 are turned ON
  5. AUX – in manual mode, zone 2 are turned ON
  6. CH/AUX – in manual mode, zone 1 and zone 2 (or HW) are turned ON

iT500RX terminals description

  Terminal name Function
L,N 230V AC power supply
CH (zone 1)
salus-it500-internet-thermostat-fig-11
NC Normally closed terminal
NO Normally open terminal
COM Common Terminal
AUX (zone 2)

or
salus-it500-internet-thermostat-fig-12

NC Normally closed terminal
NO Normally open terminal
COM Common Terminal

Wiring diagrams for single heating zone salus-it500-internet-thermostat-fig-11salus-it500-internet-thermostat-fig-13

Wiring diagram for 2 heating zones salus-it500-internet-thermostat-fig-11+salus-it500-internet-thermostat-fig-11salus-it500-internet-thermostat-fig-14

Installation of iT500RX receiver

Note: Always shut off the AC mains supply before installing or working on any components.

  1. Loosen the screws at the bottom of the receiver unit and unclip the
  2. Fit the back of the receiver unit to the wall using the fittings supplied. Then wire up the receiver using proper diagram.
  3. Clip the front of the unit back and securely screw the front of the receiver in place

salus-it500-internet-thermostat-fig-15

Fitting the wall bracket and mounting the iT300
Note:
iT300 purchased separately. Can only be used if your system supports second central heating zone

  1. Insert the 2x AAA batteries supplied in the battery case under the cover on the back of iT300 unit.
  2. Attach the wall mounting bracket to a suitable wall using the fittings supplied.
  3. Align the grooves on the back of the iT300 unit and slide onto the bracket.

salus-it500-internet-thermostat-fig-16

The post SALUS IT500 Internet thermostat Quick Guide appeared first on thermostat.guide.



source https://thermostat.guide/salus/salus-it500-internet-thermostat-quick-guide/

No comments:

Post a Comment

Blyss Valkla Digital Thermostat User Manual

Blyss Valkla Digital Thermostat What is in the box Check the contents of the packaging and the visual condition of the products. Contents of...