Friday, 3 February 2023

Daikin D4271C Digital Thermostat Owner Manual

Daikin-logo

Daikin D4271C Digital Thermostat 

Daikin-D4273-Digital-Thermostat-Owner-Manual-product

CAUTION Follow the Installation Instructions before proceeding. Set the thermostat mode to “OFF” prior to changing settings in setup or restoring Factory Defaults.

FCC Compliance Statement
This equipment has been tested and found to comply with the limits for an intentional radiator, pursuant to Part 15, subpart C of the FCC rules. These limits are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference in radio communications. However, there is no guarantee that the interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that of the receiver.
  • Consult the dealer or an experienced radio or TV technician for help.

Notice: Only peripherals complying with FCC limits may be attached to this equipment. Operation with noncompliant peripherals or peripherals not recommended by Daikin, is likely to result in interference to radio and TV reception. Changes or modifications to the product, not expressly approved by Daikin could void the user’s authority to operate the equipment.

FCC – INDOOR Mobile Radio Information:
To comply with FCC/IC RF exposure limits for general population / uncontrolled exposure, the antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter.
This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device.
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.
We, Daikin, declare under our sole responsibility that the device to which this declaration relates: Complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
FCC ID: MUH-SKYPORT4
IC: 12547A-SKYPORT4
This Explorer thermostat has the ability to receive updates to its firmware. Periodically firmware updates are released by the manufacturer to add features and/or performance enhancements. This manual was produced reflecting the most current firmware/feature set at the time of publication, firmware rev. 1.0. Firmware releases after rev. 1.0 may not be adequately depicted in this manual. Please refer to the appropriate website or contact your place of purchase to learn about changes to the thermostat after firmware release 1.0.

Daikin-D4271C-Digital-Thermostat 

Glossary of Terms

  • Auto-Changeover: A mode in which the thermostat will turn on the heating or cooling based on room temperature demand.
  • Cool Setpoint: The warmest temperature that the space should rise to before cooling is turned on (without regard to deadband).
  • Deadband: The number of degrees the thermostat will wait, once a setpoint has been reached, before energizing heating or cooling.
  • Differential: The forced temperature difference between the heat  setpoint and the cool setpoint in Auto Mode.
  • Heat Setpoint: The coolest temperature that the space should drop to before heating is turned on (without regard to deadband).
  • Icon: The word or symbol that appears on the thermostat display. Mode: The current operating condition of the thermostat (i.e. Off, Heat, Cool, Auto).
  • Non-Programmable Thermostat: A thermostat that does not have the capability of running Time Period Programming. Programmable Thermostat: A thermostat that has the capability of running Time Period Programming.
  • Temperature Swing: Same as Deadband.
  • Time Period Programming: A program that allows the thermostat to automatically adjust the heat setpoint and/or the cool setpoint based on the time of the day. Same as Schedule.

Get To Know Your ThermostatDaikin-D2111-Digital-Thermostat-1Daikin-D2111-Digital-Thermostat-2

Display FeaturesDaikin-D2111-Digital-Thermostat-3

  1. The scrolling display will be used to help you easily navigate the setup screens in the thermostat.
  2. The clock with Day of the Week Indicates the current time and day. This clock is also used to program the time period schedules.
  3. Mode Indicators
    Selects the operational mode of the equipment.
    • HEAT – Indicates the heating mode.
    • COOL – Indicates the air conditioning mode.
    • HEAT & COOL – Indicates the system will automatically change-over between heat and cool modes as the temperature varies.
    • OFF – Indicates heating and cooling is turned off.
  4. Program icon
    Indicates that Time Period Programming is running or is enabled to be set.
  5. Room Temperature Display
    Indicates the current room temperature and displays the outdoor temperature when selected.
  6. Outdoor icon
    Indicates the temperature displayed is from the optional outdoor sensor.Daikin-D2111-Digital-Thermostat-4
  7. Desired Set Temperature
    Indicates desired room temperature(s). Also displays the highest and lowest temperatures for the day.
  8. Morning, Day, Evening & Night icons
    Indicates the day part of the time period program.
  9. Wi-Fi icons
    Indicates the thermostat is currently connected to the Local Area Network, via the optional Wi-Fi module.
  10. Setup Step icon
    Indicates the step number when the thermostat is in the setup mode.
  11. 2nd Stage icons
    Indicates what stage of cooling or heating is currently energized.
  12. Daikin-D2111-Digital-Thermostat-42icon
    Indicates the keypad has been locked.Daikin-D2111-Digital-Thermostat-5
  13. AuxHeat icon
    Indicates 2nd stage electric strip heat is being used when the thermostat is programmed for Heat Pump operation.
  14. Fan On icon
    Indicates constant, continuous fan operation. When Fan On is not lit – indicates the fan will only operate when necessary to heat or to cool.
  15. Hi icon
    Indicates the highest recorded outdoor temperature for the day.
  16. Fan On icon
    Indicates constant, continuous fan operation. When Fan On is not lit – indicates the fan will only operate when necessary to heat or to cool.
    Note: Hi and Lo Temperatures for the day, reset at midnight.

Quick Start

During Setup and Programming
Press the WARMER or COOLER buttons to modify the selection. Press the MODE button to advance and confirm through the setup steps.

Setting the Clock and Day*
Not available when wi-fi module is present.
Press the SET CLOCK button. Adjust the clock using the WARMER or COOLER buttons. Press MODE to advance to the day setting. Adjust the day using the WARMER or COOLER buttons. Press the SET CLOCK button to confirm settings.
TIP: To adjust the time by hours press and hold the FAN button while pressing the WARMER or COOLER buttons.Daikin-D2111-Digital-Thermostat-6

Selecting the Heat or Cool ModeDaikin-D2111-Digital-Thermostat-7

Select mode by pressing the MODE button.

  • Heating Only – Only the heating operation will be controlled by the thermostat in this mode.
  • Cooling Only – Only the cooling operation will be controlled by the thermostat in this mode. Heating or Cooling (Auto-Changeover) – AUTO will automatically select heat or cool based on room temperature demand.
  • OFF – OFF indicates both heating and air conditioning systems are turned off.

Selecting your desired temperature

  • AUTO-CHANGEOVER MODE – Pressing the WARMER or COOLER buttons in Auto mode will adjust both the heat and cool setpoints simultaneously. To adjust heat and cool setpoints individually, choose HEAT mode to adjust the heat setpoint and COOL mode to adjust the cool setpoint, then return to AUTO mode.
  • HEAT OR COOL MODE – Pressing the WARMER or COOLER buttons in Heat or Cool mode will adjust only the heat or cool setpoints individually displayed.

Using the Fan ButtonDaikin-D2111-Digital-Thermostat-8
Fan On indicates constant fan operation. You may turn the fan on even if the thermostat is in the OFF mode. Pressing the FAN button toggles this feature on or off. If you don’t see “Fan On”, the fan is in auto mode and will only turn on during a heat or cool demand.

Using the Override ButtonDaikin-D2111-Digital-Thermostat-9

UNOCCUPIED OPERATION –
NOTE: Override may only be used when the thermostat is set to PROGRAM ON. During programmed, unoccupied periods, pressing the OVERRIDE button will force the thermostat into Occupied 1 settings for 30 minutes. Each press of the OVERRIDE button will add another 30 minutes of time for up to 4 hours. If the maximum time has been set, the next press of the OVERRIDE button will reset the timer and return the thermostat to the correct time period program for the day Occupied Operation – During programmed, occupied periods, pressing the OVERRIDE button will force the thermostat into an unoccupied period for the rest of the day. During this forced unoccupied period the OVERRIDE button will operate as described above.

Current Override Hours (setup step 11)
This counter keeps track of the number of hours that the thermostat is overridden into Occupied settings. Press FAN to reset.

Viewing the Temperature SensorsDaikin-D2111-Digital-Thermostat-9

  • OUTDOOR TEMP – Press the OUTDOOR button to view a connected outdoor wired sensor.
    If the thermostat is connected to Skyport; upon pressing the OUTDOOR button the scrolling display will read “Forecast”. The forecasted high and low temperatures for the day will be displayed.
    Press the OUTDOOR button again to view any connected outdoor wired sensor. (Remote or supply).
    Note: If no outdoor sensor is connected, and there isn’t outdoor temperature via Wi-Fi, then 2 dashes [- -] will appear with the first button press.

REMOTE/SUPPLY TEMPDaikin-D2111-Digital-Thermostat-10

Press the Accessory Status button to view linked wireless wired sensors and other accessories. Press the Accessory Status button to return to the main screen.

Installation Instructions

Remove and Replace the old thermostat
To install the thermostat properly, please follow these step by step instructions. If you are unsure about any of these steps, call a qualified technician for assistance.

  • Assemble tools: Flat blade screwdriver, wire cutters and wire strippers.Daikin-D2111-Digital-Thermostat-11
  • Make sure your Heater/Air Conditioner is working properly before beginning installation of the thermostat.
  • Carefully unpack the thermostat. Save the screws, any brackets, and instructions.
  • Turn off the power to the Heating/Air Conditioning system at the main fuse panel. Most residential systems have a separate breaker for disconnecting power to the furnace.
  • Remove the cover of the old thermostat. If it does not come off easily, check for screws.
  • Loosen the screws holding the thermostat base or subbase to the wall and lift away.
  • If you have a smart phone handy, take a photo of the wiring for future reference.
  • Disconnect the wires from the old thermostat. Tape the ends of the wires as you disconnect them, and mark them with the letter of the terminal for easy reconnection to the new thermostat.
  • Keep the old thermostat for reference purposes, until your new thermostat is functioning properly.

Wire Connections

If the terminal designations on your old thermostat do not match those on the new thermostat, refer to the chart below or the wiring diagrams that follow.

Wire from the old thermostat terminal marked  

Function

Install on the new thermostat connector marked
G or F Fan G
Y1, Y Cooling Y1
W1, W Heating W1/0/B
Rh, R, M, Vr, A Power R
C Common C
O/B Rev. Valve W1/O/B*
W2 2nd Stage Heat W2
Y2 2nd Stage Cooling Y2
W3 3rd Stage Heat W3
Ck1 Dry Contact Switch DRY CONTACT
CKGND Dry Contact Switch DRY CONTACT

Note: O/B is used if your system is a Heat Pump.

The Thermostat Backplate

To remove the thermostat backplate: Gently separate the display from the base by pulling first from one side, then the other until the two pieces unsnap. A small screwdriver may be used, very carefully, to start seperating the two pieces.Daikin-D2111-Digital-Thermostat-13 Daikin-D2111-Digital-Thermostat-12

  • R 24 VAC return
  • G Fan relay
  • W1/O/B 1st stage heat circuit
  • W2 2nd stage heat circuit
  • Y1 1st stage compressor relay
  • C 24 VAC common
  • OUTDOOR Outdoor sensor
  • SENSOR connections
  • DRY Dry Contact
  • CONTACT connections

IMPORTANT: This thermostat requires both R (24 VAC Return) and C (24 VAC Common) be connected to the backplate terminals.

Check Dip Switch

Ensure which switch is correct for your system. Dip switches are located on the back of the thermostat.Daikin-D2111-Digital-Thermostat-14

  1. When GAS/EL or HP is set for GAS/EL:
    This switch (GAS or ELEC) controls how the thermostat will control the Fan (G) terminal
    in heating mode. When GAS is chosen, the thermostat will not energize the Fan (G) terminal in heating. When ELEC is chosen the thermostat will energize the fan in heating.
  2. When GAS/EL or HP is set for HP:
    This switch (GAS or ELEC) defines the Aux Heat type. When GAS is chosen, the auxiliary heat will not be allowed to run during heat pump operation. When ELEC is chosen, up to two stages of auxiliary strip heat will be allowed to run.Daikin-D2111-Digital-Thermostat-15

For Heat Pump Only
When the GAS/EL or HP dip switch is configured for HP, this dip switch (O or B) must be set to control the appropriate reversing valve. If O is chosen, the W1/O/B terminal will energize in cooling. If B is chosen, the W1/O/B terminal will energize in heating.Daikin-D2111-Digital-Thermostat-16

This dip switch configures the thermostat to control a conventional gas/electric system or a heat pump. If your system is anything other than a heat pump, leave this switch set for GAS/EL. Daikin-D2111-Digital-Thermostat-17

Sample Wiring Diagrams

Conventional Heating and Cooling SystemsDaikin-D2111-Digital-Thermostat-19 Daikin-D2111-Digital-Thermostat-20

Heat Pump SystemsDaikin-D2111-Digital-Thermostat-21

Dry ContactDaikin-D2111-Digital-Thermostat-20

Test Operation

The technician setup is a diagnostic feature that enables testing of all outputs. To enter Technician Setup, press and hold the SETUP button for 10 seconds until all the icons appear. Follow the next steps to view settings and test equipment.

  1. Press MODE to view the version numbers of the thermostat.
  2. Press MODE again to view the jumper settings and current state of the Dry Contact terminals.
  3. Press MODE again and the scrolling display will read “TURN ON EQUIPMENT?” Press WARMER for Yes or COOLER for No.
    If Yes is chosen, press WARMER to turn on heat or COOLER to turn on Cooling. The scrolling display will read “NOTHING ON.” Next:
    Press WARMER to turn on and cycle up through the heating stages.
    Press COOLER to turn the heating stages off. Press MODE to exit.
    Press COOLER to turn on and cycle down through the cooling stages.
    Press WARMER to turn the cooling stages off. Press MODE to exit.
  4. Press MODE until “CALIBRATE SENSORS?” appears on the scrolling display. Press WARMER for Yes or COOLER for No. Press MODE to select which sensor to calibrate. Use WARMER or COOLER to modify your selection.
    To exit Technician Setup at any time, press the SETUP button. Technician Setup will automatically exit after 10 minutes if no buttons are pressed.

User Setup

Backlight OperationDaikin-D2111-Digital-Thermostat-23

How to Change Settings in the Setup Screens
To enter Advanced Setup, press the SETUP button, then press MODE. Use the WARMER or COOLER buttons to adjust the value of your selection. Press MODE to advance to the next setup step. Press SETUP again to leave the setup screens.

Backlight (Setup Steps 3-8)

Backlight (setup step 3)

  • Off – Backlight turns on with any button press and turns off after 8 seconds.
  • On – Backlight is on continuously.

Backlight Intensity Level (setup step 4)
The backlight can be adjusted between Off and seven levels of brightness.

Night Dimmer (setup step 5)
Selecting On allows for automatic dimming of the display at night.

Night Dimmer Brightness (setup step 6)
Off through seven levels of brightness

Night Dimmer Start Time (setup step 7)
12:00 am to 12:00 am

Night Dimmer Stop Time (setup step 8) 
12:00 am to 12:00 am

Language (Setup Step 16)
Setup step instructions on the scrolling display can be set for English, Spanish, or French. Press the SETUP button, then press MODE repeatedly until the Language setup step appears. Use the WARMER or COOLER buttons to make selection. Press MODE to advance to the next step. Press SETUP to leave the setup screens.

Scrolling Screen and Display Options

Scrolling Display Method (Setup Step 17)
This option allows the user to choose how the scrolling text is displayed. Options are:Daikin-D2111-Digital-Thermostat-22

Press the SETUP button, then press MODE repeatedly until the Scrolling Method setup step appears. Use the WARMER or COOLER buttons to make selection. Press MODE to advance to the next step. P ress SETUP to leave the setup screens.

Daikin-D2111-Digital-Thermostat-21

Example of “Whole Words Centered”:

Daikin-D2111-Digital-Thermostat-24

HolidayDaikin-D2111-Digital-Thermostat-27

The Holiday feature allows the thermostat to use temporary, energy saving settings without having to change regular programming. Holiday setup/programming at the local thermostat is limited to the number of days employing Holiday settings. When the optional Wi-Fi module is detected in the thermostat, local Holiday programming at the thermostat of the Holiday setup is not allowed. In this case Holiday setup and programming is accomplished with the Skyport Web App. Skyport gives the user extensive control over Holiday settings. Press the HOLIDAY button to enter Holiday programming. (no Wi-Fi Module detected).

If there is not a Holiday period active:

  • Use the WARMER and COOLER buttons to choose the number of days desired to run the Holiday feature. To confirm your setting press the HOLIDAY button again.
  • When the thermostat is programmed for Holiday operation, and the thermostat is in the Program On mode (running an Occupied/Unoccupied time period schedule), Holiday settings will take effect at 12:00AM of the next day. The thermostat will use the unoccupied mode and setpoints (see page 27) during the holidays.

If the Holiday button is pressed during an active Holiday period:
The active Holiday period may be cancelled by pressing the Mode button.

If there is not a Holiday period active:
Use the WARMER and COOLER buttons to choose the number of days desired to run the Holiday feature. To confirm your setting press the HOLIDAY button again.
When the thermostat is programmed for Holiday operation, and the thermostat is in the Program On mode (running an Occupied/Unoccupied time period schedule), Holiday settings will take effect at 12:00AM of the next day. The thermostat will use the unoccupied mode and setpoints (see page 27) during the holidays.

Emergency HeatDaikin-D2111-Digital-Thermostat-28

The Emergency Heat function is only available if your thermostat is set to control a Heat Pump. To initiate the Emergency Heat feature, Press the EMERGENCY button. During Emergency Heat operation the thermostat will turn on the fan and auxiliary stages of heat when there is a demand for heat. The 1st stage of heating and all stages of cooling will be unavailable. To exit Emergency Heat, press the EMERGENCY button.

Wireless ModulesDaikin-D2111-Digital-Thermostat-27

The Accessory Status button allows the user to view the status of wired and wireless accessories. For many of the wireless devices this status includes: Battery Level, Signal Strength & Last Time Updated.
If there is an optional wireless module installed, the Accessory Setup button allows the user to link or connect wireless devices to the thermostat, or the thermostat to the network.

Wi-Fi ModuleDaikin-D2111-Digital-Thermostat-28

Please follow the instructions included with the Wi-Fi module to connect to an Access Point or view status. The general instructions are below.
If the WIFI  is present on the display then the thermosat is connected to the Wi-Fi  Access Point. If just the “dot” of this icon appears, then just the Wi-Fi module is recognized.
Press the Accessory Status button, then press either the Cooler button to view connected Wi-Fi sensors, OR press the Warmer button to view the Wi-Fi status and settings.
Press the Mode button to step through the connected sensors or the Wi-Fi status screens listed below.

  • a. Wi-Fi status (connecting, connected, etc.)
  • b. Signal strength
  • c. Access point name
  • d. IP address
  • e. MAC address
  • f. Skyport status (connecting, connected, etc.)
  • g. Local API status (Enabled, Disabled)
  • h. Module version

At any time press the Accessory Status button to leave the status screens.
Press the Accessory Setup button to enter Wi-Fi or Skyport setup:
Press the Cooler button to configure Wi-Fi settings.
Press the Warmer button to join this thermostat to a Skyport account. If the theremostat is connected to Wi-Fi and the Internet, a Device ID will appear on the scrolling display of the thermostat. You will enter this code to add this thermostat to your Skyport account via a browser or the Skyport mobile app.
Note: To connect to Skyport Cloud Services, Setup Step #27 must be set to on.

Service Filter

These setup steps allow the user to monitor equipment runtimes and program service alerts. Service alerts are displayed in the scrolling marquee.Daikin-D2111-Digital-Thermostat-29

Service Filter Runtime (Setup Steps 9-10, 12-13)

  • Current Service Filter Runtime Hours (Setup Step 9) – This counter keeps track of the number of hours of fan runtime in the Heating mode, Cooling mode, and in stand alone Fan operation. Press FAN to reset.
  • Current Service Filter Calendar Days (Setup Step 10) – This counter displays the total number of calendar days that have elapsed since the counter was reset to help the user track Fan runtime. Press FAN to reset.
  • Set Service Filter Runtime Hours (Setup Step 12) – This timer allows the user to specify the number of hours the fan will run before the “Replace Filter”  alert will be displayed. Press COOLER continuously until OFF is displayed to disable this alert.
  • Set Service Filter Calendar Days (Setup Step 13) – This timer allows the user to specify the number of calendar days that will elapse before the “Replace Filter” alert will be displayed. Press COOLER continuously until OFF is displayed to disable this feature.
    Press the SETUP button, then press MODE repeatedly until the desired setup step appears. Use the WARMER or COOLER buttons to make selection. Press MODE to advance to the next step. Press SETUP to leave the setup screens. Daikin-D2111-Digital-Thermostat-31

System Runtimes

To view, set, or reset System Runtimes, press the SETUP button, then press MODE. Press MODE to advance to the desired setup step. Use the WARMER or COOLER buttons to adjust the value of your selection. Press SETUP again to leave the setup screens.

UV Lamp Runtime (setup steps 12, 15)
Current UV Lamp Calendar Days (setup step 12) – This counter displays the total number of calendar days that have elapsed since last reset to help the user track UV lamp runtime. Press FAN to reset. Set UV Lamp Calendar Days (setup step 15) – This timer allows the user to specify the number of calendar days the UV Lamp will operate before the “Replace UV Lamp” alert will be displayed. Press COOLER continuously until 0 appears to disable this alert.

Time Period Programming

Selecting Your Time Period Schedule (setup step 1)
This thermostat may be configured to be programmable or non programmable.

  • 7 Day Program – Allows all seven days to be programmed independently.
  • Non Program – No advanced time period programming available.
  • 1 Day Program – Allows one 24 hour day to be programmed. This same schedule will be repeated every day the program is set to run.
  • 5/1/1 Day Program – Allows weekdays, Saturday, and Sunday to be programmed independently.

Selecting Your Available Modes (setup step 2)

  • Auto-Changeover – Allows the thermostat to turn on heating or cooling based on room temperature demand. Also allows the manual selection of HEAT only or COOL only and OFF.
  • Heat and Cool – Allows the thermostat to turn on heating or cooling depending on which one has been manually selected. Auto-Changeover is not available when this is selected.
  • Heat Only – Allows the thermostat to only turn on HEAT or OFF modes.
  • Cool Only – Allows the thermostat to only turn on COOL or OFF modes.

Programming a Daily Time Period Schedule
not available when wi-fi module is present
To enable (RUN) or turn ON the Time Period Schedule press the Program button momentarily.
To turn Off the Time Period Schedule stored program press this button again.
To alter the Time Period Schedule settings; press & hold this button for 5 seconds until the “Set Program” prompt appears. Modify the settings with the Warmer and Cooler buttons. Use the Mode button to advance through the steps. Press the Program button again to leave the setup screens.

Program ButtonDaikin-D2111-Digital-Thermostat-31

Programming a Daily Schedule*

Once the Set Program prompt appears the Mode button will step you through the settings as follows:

  • Set the Unoccupied Mode – Press the Warmer or Cooler buttons to choose the mode for the Unoccupied period. The thermostat is in Unoccupied when the Time Period Schedule is running and there is not an active Occupied period. The choices are: Off, Heat only, Cool only and AUTO changeover.
  • Adjust the Unoccupied Cool Setpoint – Press the Warmer or Cooler buttons to adjust the Cooling setpoint for times when the thermostat is in Unoccupied.
  • Adjust the Unoccupied Heat Setpoint – Press the Warmer or Cooler buttons to adjust the Heating setpoint for times when the thermostat is in Unoccupied.
  • Select the number of Occupied time periods – Press the Warmer or Cooler buttons to choose the maximum number (up to 3 maximum) of Occupied time periods in a day.
  • Select the Mode for the Occupied period – Press the Warmer or Cooler buttons to choose the mode for the occupied period. The choices are: Off, Heat only, Cool only and AUTO changeover.
  • Adjust the Occupied Cool Setpoint – Press the Warmer or Cooler buttons to adjust the Cooling setpoint for comfort.
  • Adjust the Occupied Heat Setpoint – Press the Warmer or Cooler buttons to adjust the Heating setpoint for comfort.

The following steps determine when the Occupied period(s) will be active.

  • Enable Occupied 1 – Press the Warmer or Cooler buttons to enable (On) or to disable (Off) Occupied 1 on Monday.
  • Adjust the Start Time for Occupied 1 – Press the Warmer or Cooler buttons to adjust the start time for Occupied 1 on Monday.
  • Adjust the Stop Time for Occupied 1 – Press the Warmer or Cooler buttons to adjust the stop time for Occupied 1 on Monday.

Upon pressing Mode after the above step; you will be prompted to Save and Exit or Copy this Occupied schedule to another day.

  • To save and exit – Press the Program button.
  • To Copy Monday’s settings/schedule to Tuesday – Press Up and then Mode. Press Mode again to copy the Monday Settings/schedule to subsequent days.
  • To Program Another Day – Press Down and then press the Mode button to select the day to program. Repeat the above steps for each day you would like to program.

Installer Setup

Setpoint Limits

Setpoint Limits (setup step 18) When this feature is at any setting other than no setpoint limits’, the heat and cool setpoints can be restricted to preset levels, set in steps 19 and 20.
This feature allows the user to set 3 different levels of security: (0 – 3).

No Setpoint Limits (0) – When this level is selected, no restrictions are activated.

Use Setpoint Limits (1) – When this level is selected, the heat and cool setpoints can be restricted to preset levels, set in setup steps 19 and 20.

  • Maximum Heat Setpoint (setup step 19) – (35˚ – 99˚).
  • Minimum Cool Setpoint (setup step 20) – (35˚ – 99˚).

Force Program Mode (2) – When this level is selected, the heat and cool setpoints can be restricted to preset levels, set in setup steps 19 and 20 and the thermostat is locked into the current mode and time period program setting and the FAN button is locked out.

Setpoints Frozen (3) – When this level is selected, the heat and cool setpoints, the current mode, the FAN button and time period program settings are locked.

Cycles Per Hour (setup step 21) The Cycles Per Hour setting may limit the number of times per hour your HVAC unit may energize. For example, at a setting of 6 cycles per hour the HVAC unit will only be allowed to energize once every 10 minutes. The Cycles Per Hour limit may be overridden and reset by pressing the WARMER or COOLER buttons on the thermostat. Settings are No Limit, 2, 3, 4, 5, or 6.

Compressor Minimum Off Minutes (setup step 22) This feature
allows the user to set a minimum off time for the compressor. Settings are 5 mins., 3 mins., or 0 mins.

Minimum Heat/Cool Setpoint Difference (setup step 23)
This feature allows the user to set the minimum gap between Heat and Cool setpoints in AUTO mode. Select from 0 to 6. If setup step 2 is not set for AUTO-CHANGEOVER, this step will not appear.

Number of Heat Stages (setup step 24) This setting assures proper stage callouts on the thermostat display for non-heat pump applications.

Number of Cool Stages (setup step 25) This setting assures proper stage callouts on the thermostat display for non-heat pump applications.

Number of Compressor Stages (setup step 26) This feature is for heat pump application only. This feature allows the thermostat to control 1 or 2 compressor stages when configured for heat pump.

Number of Aux Stages (setup step 27) This feature is for heat pump application only. This feature allows for proper Aux Heat Staging. (0-2 stages)

Timers and Deadbands

Deadband Settings (setup steps 28 – 37)
The Deadband is the number of degrees or minutes that the thermostat waits before it initiates the stages of heating or cooling.

  • 1st Stage Deadband (setup step 28) – Specifies the minimum temperature difference between the room temperature and the desired setpoint before the first stage of heating or cooling is allowed to turn on. (1 – 6 degrees) For example, if the heat setpoint is 68˚ and the 1st Stage deadband is set to 2 degrees, the room temperature will need to reach 66˚ before the heat turns on.
  • 2nd Stage Deadband (setup step 29) – Specifies the additional minimum temperature difference after the first stage turns on before the second stage is activated. (0˚ – 10˚)
  • 3rd Stage Deadband (setup step 30) – Specifies the additional minimum temperature difference after the second stage turns on before the third stage is activated. (0˚ – 10˚)
  • 4th Stage Deadband (setup step 31) – (Two Stage heat pump only) – Specifies the additional minimum temperature difference after the third stage turns on before the final stage of strip heat is activated. (0˚ – 10˚)
  • Minutes Between 1st and 2nd Stage (setup step 32) – Specifies the minimum time (in minutes) after the first stage turns on before the second stage can turn on. (0 – 60)
  • Minutes Between 2nd and 3rd Stage (setup step 33) – Specifies the minimum time (in minutes) after the second stage turns on before the third stage can turn on. (0 – 60)
  • Minutes Between 3rd and 4th Stage (setup step 34) – Specifies the minimum time (in minutes) after the third stage turns on before the final stage can turn on. (0 – 60)
  • Second Stage Turnoff Point (setup step 35) – Specifies whether second stage will turn off at first stage deadband or remain on until the room temperature demand is satisfied. Choose between Deadband or Setpoint.
  • Third Stage Turnoff Point (Setup Step 36) – Specifies whether third stage will turn off at second stage deadband or remain on until the room temperature demand is satisfied. Choose between Deadband or Setpoint.
    Fourth Stage Turnoff Point (Setup Step 37) – Specifies whether fourth stage will turn off at third stage deadband or remain on until the room temperature demand is satisfied. Choose between Deadband or Setpoint.

Programming Fan Operation

Minutes of Fan Purge (setup step 38)
When this feature is activated, the fan will turn on during an unoccupied period at a preset amount of time prior to Occupied 1. This preoccupancy fan purge timer may be set from zero to three hours, in 15 minute increments. Zero means this feature is turned off.

Fan Off Delay in Seconds (setup step 39)
This feature allows the user to increase the cooling or electric strip heating efficiency of the system. The thermostat may be programmed to continue running the fan after a call for cooling or electric strip heating has been satisfied. This delay can be set for 0, 30, 60, 90, or 120 seconds. If set to 0, the fan will not run after a call for cooling or electric strip heating has been satisfied.

Comfort Recovery (setup step 41)
With Comfort Recovery on, the thermostat will attempt to reach the Occupied 1 setpoint temperature at the exact time programmed into the thermostat. Comfort Recovery, only works when the thermostat enters the Occupied mode from the Unoccupied mode. For example, if the Occupied program is set for 6am at 72°F heating and 75°F cooling, the thermostat will turn the system on before 6am in an effort to bring the temperature to its correct setting at exactly 6am. The thermostat learns from experience, so please allow 4-8 days after a program change or after initial installation to give Comfort Recovery time to adjust. If used with a heat pump, electric strip heat will be disabled while Comfort Recovery is active.

Dry Contact Operation (setup step 42 – 43)

Dry Contact Polarity (setup step 42)
Open (Normally Open) – The dry contact is open until the connected device closes the circuit.

Dry Contact Use (setup step 43)

  • CONDENSATE – If CONDENSATE is selected when the dry contact is active, the thermostat will lockout the compressor terminal(s) and “CONDENSATE PAN OVERFLOW” will appear on the display.
  • OCCUPIED – If OCCUPIED is selected, when the dry contact is active, the thermostat will be forced into the programmed occupied mode / setpoints and the ‘occupied’ icon will blink. This setting is useful for allowing a twist timer to force occupied settings.
  • FDD – If FDD is selected when the dry contact is active, “EQUIPMENT FAULT” will appear on the display.
  • Holiday – If HOLIDAY is selected, when the dry contact is active, the thermostat will be forced into the programmed unoccupied mode / setpoints and the ‘unoccupied’ icon will blink.

Skyport (setup step 44)
Set to ON to allow access to Skyport services or to OFF to not allow access to Skyport services.

Local API (setup step 45)
Set to ON to allow 3rd party software to interface with your thermostat such as home automation software.

Fahrenheit or Celsius (setup step 40)
This feature allows the thermostat to display temperature in Fahrenheit or Celsius.

Press Fan To Clear All Messages (setup step 54)
This feature allows the user to clear all current error messages from the display.

This thermostat features four programmable time periods per 24 hour day:
Morning, Day, Evening, and Night. The start time for each time period is adjustable. The stop time for each time period is the start time for the next period. Each time period, or day part may be individually disabled.

Select the Day to Program – Press the WARMER or COOLER to select the desired Day or Week Part in the case of 5-2 (weekday – weekend) programming.
Enable/Disable Morning Period – Press the WARMER or COOLER to select ON or OFF. If the default ON is selected, then the Morning period will run complete with the Mode and Set Points selected. If OFF is selected then the Morning day part will be skipped and the thermostat will use the next day part that is enabled.
Select Morning Mode – Press the WARMER or COOLER to select the desired mode, which includes OFF. You may be limited by the available modes in advanced Installer setup step#2. Press MODE to advance to the next step.
Select Morning Start Time – Press the WARMER or COOLER buttons to adjust the time of day desired. Press MODE to advance to the next step.
Select Morning Cool Setpoint – Press the WARMER or COOLER buttons to adjust the cool setpoint desired. This step will appear if Cool or Auto Mode was selected in the step where the Morning mode is specified. Press MODE to advance to the next step.
Select Morning Heat Setpoint – Press the WARMER or COOLER buttons to adjust the heat setpoint desired. This step will appear if Heat or Auto Mode was selected in the step where the Morning mode is specified. Press MODE to advance to the next step.
Repeat Enable, Mode, Start Time and Setpoint programming for Day, Evening, and Night.
“Copy Current Day to Next Day” is available – Press the UP button to Copy the current day’s program to the next day. Press Mode again to continue copying the following day.
Press the PROGRAM Button to exit Time Period Programming at any time.

Installer Setup

Automated Demand Response

Overview
Daikin Digital thermostats support the handling of specific signals from the utility provider. The utility generated signals carry pricing information and/or setback actions that alter the comfort settings of the thermostat in order to reduce energy usage on demand. This is known as Automated Demand Response or ADR for short. You must register to participate
in a utility sponsored program, if offered by your local utility, to take advantage of this feature.

Skyport Cloud Services
From the web application the user will select Thermostat Settings from the left column. Then the Demand Response button is selected.Daikin-D2111-Digital-Thermostat-37

The Demand Response configuration page, shown below, is where the thermostat is configured to respond to the energy provider’s signals. It also sets operational parameters for the thermostat.
The left column of the ADR configuration page allows or prevents access by the utility. Here communication with the utility and your thermostat may be turned On or Off.
The selected utility will provide a Program ID.
The Account ID would normally be the occupants utility account number.Daikin-D2111-Digital-Thermostat-38

The right column of the ADR configuration page is where the occupant adjusts the operational parameters for ADR. The utility may send up to 3 types of ADR signals to Skyport. These are:
1) Pricing for the cost of energy, 2) An Offset to the occupants’ comfort setpoints, and 3) a signal to enforce discrete or Static setpoints.
The Maximum Cooling Setpoint and Minimum Heating Setpoints for ADR events are adjusted here.
The Static Settings are applied when the utility sends a signal to allow the occupant to enforce their own discrete temperature settings during an ADR event.
The Offset Settings allow the utility to modify the Cool or Heat setpoints by the value set here during an ADR event.
A Price Trigger setting allows the occupant to set the maximum cost of energy threshold. When this threshold is exceeded
the Price dependent action is enforced. This Price Trigger and Dependent action is enforced independent of an ADR event, as long as the utility sends ‘real-time’ pricing.Daikin-D2111-Digital-Thermostat-39

Selecting the Overview tab of the ADR page will cause a summary of ADR events to be displayed.Daikin-D2111-Digital-Thermostat-40

ADR (setup step 46)
Controls whether you want the thermostat to possibly respond to signals from the utility provider. Select ON to allow this and to have steps 30-36 appear.

Price Dependent Action (setup step 47)
Allows the user to determine what action is taken when the price rises above the set threshold. Note that the threshold price is only adjustable via Skyport.

  • None – take no action when the set price threshold is exceeded
  • Observe Setpoint Offsets – will offset the heat and cool setpoints by the amounts specified in setup steps 52 and 53
  • Observe Static Setpoints – will set the heat and cool setpoints to the values specified in setup steps 50 and 51
  • Event Max Cool Setpoint (setup step 48)
  • Event Min Heat Setpoint (setup step 49)

Specifies the range of allowable setpoint adjustments to be enforced when any ADR signal has been received from the utility. Since you might be paying more for energy while an event is active, you can impose tighter limits on setpoint ranges that are only enforced during the event.

  • Static Cool Setpoint (setup step 50)
  • Static Heat Setpoint (setup step 51)

Specifies the setpoints that will come into use during an event when the PRICE DEPENDENT ACTION is set to OBSERVE STATIC SETPOINTS

  • Cool Setpoint Offset (setup step 52)
  • Heat Setpoint Offset (setup step 53)

Specifies how much the current setpoints in effect prior to an event will be altered during an event when the PRICE DEPENDENT ACTION is set to OBSERVE SETPOINT OFFSETS. The heat setpoint can be automatically lowered by 1 to 10 degrees while the cool setpoint can be automatically raised by 1 to 10 degrees

DISPLAY INDICATIONS WHEN AN ADR EVENT IS HAPPENING
After setting your desired values for use during an ADR event, the scrolling display will give a little information when an event is pending or active. For instance, when an ADR event has been sent to your thermostat, you might see ADR STARTS at 4:15 to notify you of a pending event. Once active, you might see ADR STOPS at 5:30. If you have configured a threshold for cost of energy past which you want to trigger an event, you will see PRICING EVENT on the display. When an event is active, you can press any of COOLER, WARMER or MODE buttons, followed by the WARMER to opt out of the event.

Locking/Unlocking the Keypad

To prevent unauthorized use of the thermostat, the front panel buttons may be disabled. To disable, or ‘lock’ the keypad, press and hold the MODE button. While holding the MODE button, press the WARMER and COOLER buttons together. The Daikin-D2111-Digital-Thermostat-42icon will appear on the display, then release the buttons.Daikin-D2111-Digital-Thermostat-41

To unlock the keypad, press and hold the MODE button. While holding the MODE button, press the WARMER and COOLER buttons together. TheDaikin-D2111-Digital-Thermostat-42 icon will disappear from the display, then release the buttons.

Installer Setup

 

Technician Setup

To enter Technician Setup, press and hold the SETUP button for 5 seconds. After all the icons appear, press MODE. The version number of the thermostat will appear in the scrolling text. Press MODE to advance to the next step. Use the WARMER or COOLER buttons to adjust the value of your selection. To leave Technician Setup, press SETUP.Daikin-D2111-Digital-Thermostat-43

Technician Setup is for diagnostic and testing purposes and is intended for use by a qualified technician. See page 15 for more detailed instructions.
Technician Setup contains the following options:

  • View the version number of the thermostat.
  • View the jumper setting of J1 (Gas/Electric or Heat Pump), J2 (Reversing Valve: RV=O or RV=B), and J3 (Fan: Gas or Electric) jumpers located on the back of the thermostat. (Remove thermostat from backplate for access)
  • View the state of the Dry Contact and Fault terminals.
  • Turn on equipment outputs for testing.
  • Calibrate thermostat and remote sensors.

Advanced Setup Table

Step# Description Pg# Range Default
1 Prog Mode 24 Non, 1 Day, 5/1/1 Day, 7 Day 7
2 Available Modes 24 Heat/Cool/Auto/Off,

Heat/Cool/Off, Heat/Off, Cool/Off

Heat/Cool/

Auto/Off

3 Backlight 17 On, Off Off
4 Backlight Level 17 Off thru 7 levels of brightness Level 5
5 Night Dimmer 17 On/Off Off
6 Night Dimmer Brightness 17 Off thru 7 levels of brightness 2 (20%)
7 Night Dimmer Start Time 17 12A-12A 8:00P
8 Night Dimmer Stop Time 17 12A-12A 6:00A
9 Current Service Filter Runtime Hours 22 0-1999 Hours 0
10 Current Service Filter Calendar Days 22 0-720 Days 0
11 Current Override Hours 7 0-1999 Hours 0
12 Current UV Lamp Calendar Days 23 0-720 Days 0
13 Set Service Filter Runtime Hours 22 0-1950 hours 0
14 Set Service Filter Calendar Days 22 0-720 Days 0
15 Set UV Lamp Calendar Days 23 0-720 Days 0
16 Language 17 English, Espanol, Francais English
17 Scrolling Method 18 “L-R Slow, L-R Fast, Word L-R Slow, Word L-R Fast,

Whole Word L Slow, Whole Word R Slow, Whole Word Ctr.

Fast, Whole Word Ctr. Slow”

“Whole Words Center Fast”
18 Setpoint Limits 26 0 – 3 0
19 Max Heat Setpoint 26 35 – 99 Degrees 74
20 Min Cool Setpoint 26 35 – 99 Degrees 70
21 Cycles Per Hour 26 No Limit, 2, 3, 4, 5, 6 6
22 Compressor Minimum Off Minutes 26 0, 3, 5 Minutes 5
23 Min. Heat/Cool Setpoint Difference 26 0 – 6 Degrees 2
24 Number of Heat Stages 26 0 – 3 2
25 Number of Cool Stages 26 0 – 2 1
26 Number Of Compressor Stages 26 1, 2 1
27 Number of Aux Stages 26 0, 1, 2 0
28 1st Stage Deadband 27 1 – 6 Degrees 2
29 2nd Stage Deadband 27 0 – 10 Degrees 2
30 3rd Stage Deadband 27 0 – 10 Degrees 2
31 4th Stage Deadband 27 0 – 10 Degrees 2
32 Minutes Between 1st and 2nd Stage 27 0 – 60 Minutes 2
33 Minutes Between 2nd and 3rd Stage 27 0 – 60 Minutes 2
34 Minutes Between 3rd and 4th Stage 27 0 – 60 Minutes 2
Step# Description Pg# Range Default
35 2nd StageTurnoff Point 27 Deadband, Setpoint Deadband
36 3rd StageTurnoff Point 27 Deadband, Setpoint Deadband
37 4th Stage Turnoff Point 27 Deadband, Setpoint Deadband
38 Minutes fo Fan Purge 28 0 – 3:00, 15 min. increments

– 0 = off

0
39 Fan Off Delay 28 0 – 120 Seconds 0
40 F/C 29 Fahrenheit (F), Celsius (C) F
41 Comfort Recovery 28 On, Off Off
42 Dry Contact Polarity 29 Open, Closed Open
43 Dry Contact Use 29 Condensate Pan, Occupied,

FDD, Holiday

44 Skyport 29 On, Off On
45 Local API 29 On, Off Off
46 ADR 34 On, Off Off
47 Price Dependent Action 34 None, Observe Setpoint Offset, Observe Static Setpoints  

None

48 Event Max Cool Setpoint 34 65 – 85 85
49 Event Min Heat Setpoint 34 65 – 85 65
50 Static Cool Setpoint 34 65 – 85 78
51 Static Heat Setpoint 34 65 – 85 68
52 Cool Setpoint Offset 35 1 to 10 2
53 Heat Setpoint Offset 35 -1 to -10 -2
54 Press Fan To Clear All Messages 29

Troubleshooting

  • SYMPTOM: The air conditioning does not attempt to turn on. CAUSE: The compressor timer lockout may prevent the air conditioner from turning on for a period of time.
    REMEDY: Consult the Owner’s Manual in the Installer Setup section to defeat the Cycles Per Hour (page 28).
  • SYMPTOM: The display is blank.
    CAUSE: Lack of proper power.
    REMEDY: Make sure the power is on to the furnace and that you have 24vac between R & C.
  • SYMPTOM: When controlling a residential heat pump, and asking for cooling, the heat comes on.
    CAUSE: The thermostat reversing valve jumper is set for “B”. REMEDY: Set the reversing valve jumper for “O”.
  • SYMPTOM: When calling for cooling, both the heat and cool come on. CAUSE: The thermostat equipment jumper is configured for “HP” and the HVAC unit is a Gas/Electric.
    REMEDY: Set the equipment jumper for “Gas”.
  • SYMPTOM: When the Program button is pressed, the display reads “DISABLED”.
    CAUSE: Program mode is set to “NON PROGRAM”.
    REMEDY: Set Program Mode (Setup 1) to 1, 5/2, or 7 Day.
    See Selecting Your Program Mode (page 21).

Warranty

One-Year Warranty – This Product is warranted to be free from defects in material and workmanship. If it appears within one year from the date of original installation, whether or not actual use begins on that date, that the product does not meet this warranty, a new or remanufactured part, at the manufacturer’s sole option to replace any defective part, will be provided without charge for the part itself provided the defective part is returned to the distributor through a qualified servicing dealer.
THIS WARRANTY DOES NOT INCLUDE LABOR OR OTHER COSTS incurred for diagnosing, repairing, removing, installing, shipping, servicing or handling of either defective parts or replacement parts. Such costs may be covered by a separate warranty provided by the installer.
THIS WARRANTY APPLIES ONLY TO PRODUCTS IN THEIR ORIGINAL INSTALLATION LOCATION AND BECOMES VOID UPON REINSTALLATION.
LIMITATIONS OF WARRANTIES – ALL IMPLIED WARRANTIES (INCLUDING IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND MERCHANTABILITY) ARE HEREBY LIMITED IN DURATION TO THE PERIOD FOR WHICH THE LIMITED WARRANTY IS GIVEN. SOME STATES DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE MAY NOT APPLY TO YOU. THE EXPRESSED WARRANTIES MADE IN THIS WARRANTY ARE EXCLUSIVE AND MAY NOT BE ALTERED, ENLARGED, OR CHANGED BY ANY DISTRIBUTOR, DEALER, OR OTHER PERSON WHATSOEVER.
ALL WORK UNDER THE TERMS OF THIS WARRANTY SHALL BE PERFORMED DURING NORMAL WORKING HOURS. ALL REPLACEMENT PARTS, WHETHER NEW OR REMANUFACTURED, ASSUME AS THEIR WARRANTY PERIOD ONLY THE REMAINING TIME PERIOD OF THIS WARRANTY.
THE MANUFACTURER WILL NOT BE RESPONSIBLE FOR:

  1. Normal maintenance as outlined in the installation and servicing instructions or owner’s manual, including filter cleaning and/or replacement and lubrication.
  2. Damage or repairs required as a consequence of faulty installation, misapplication, abuse, improper servicing, unauthorized alteration or improper operation.
  3. Failure to start due to voltage conditions, blown fuses, open circuit breakers or other damages due to the inadequacy or interruption of electrical service.
  4. Damage as a result of floods, winds, fires, lightning, accidents, corrosive environments or other conditions beyond the control of the Manufacturer.
  5. Parts not supplied or designated by the Manufacturer, or damages resulting from their use.
  6. Manufacturer products installed outside the continental U.S.A., Alaska, Hawaii, and Canada.
  7. Electricity or fuel costs or increases in electricity or fuel costs for any reason whatsoever including additional or unusual use of supplemental electric heat.
  8. ANY SPECIAL INDIRECT OR CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGE OF ANY NATURE WHATSOEVER. Some states do not allow the exclusion of incidental or consequential damages, so the above may not apply to you.

This warranty gives you specific legal rights and you may also have other rights which may vary from state to state.

Programming Worksheet

see page 23

DAY PERIOD START TIME COOL HEAT
MONDAY Morning
Day
Evening
Night
TUESDAY Morning Copy Mon to TuesNo Yes
Day
Evening
Night
WEDNESDAY Morning Copy Tues to WedNo Yes
Day
Evening
Night
THURSDAY Morning Copy Wed to ThursNo Yes
Day
Evening
Night
FRIDAY Morning Copy Thurs to FriNo Yes
Day
Evening
Night
SATURDAY Morning Copy Fri to SatNo Yes
Day
Evening
Night
SUNDAY Morning Copy Sat to SunNo Yes
Day
Evening
Night

Daikin

Daikin D4271C Digital Thermostat Owner Manual

The post Daikin D4271C Digital Thermostat Owner Manual appeared first on thermostat.guide.



source https://thermostat.guide/daikin/daikin-d4271c-digital-thermostat-owner-manual/

No comments:

Post a Comment

Blyss Valkla Digital Thermostat User Manual

Blyss Valkla Digital Thermostat What is in the box Check the contents of the packaging and the visual condition of the products. Contents of...