Monday, 6 February 2023

SALUS EP210 Dual channel programmable Thermostat Installation Manual

SALUS logo

SALUS EP210 Dual channel programmable Thermostat

SALUS EP210 Dual channel programmable Thermostat product

Introduction

The EP210 dual-channel programmable controller is a stylish wired timer that can be used for central heating and also for hot water. Each output will control one zone, meaning that you can create personalized schedules for each channel.
The EP210 programmable controller will switch ON and OFF your central heating system and/or hot water in your home as needed. It works by controlling the heating boiler according to a series of programmed settings that take effect at different times of the day.
By using the EP210 controller you can manage the commands sent to your boiler, motorized valves used in your system or to your thermostat. You can set the EP210 programmable controller to a 12 or 24-hour format, the Daylight saving Time (DST) being automatically enabled. The program mode is also selectable between a 5-2 (Monday-Friday and Saturday-Sunday) or 24-hour format. For each of the programs, you can create three settings per day.

Being a complex programmable controller, the EP210 gives you the possibility to override your programs by using the Boost function. This can be enabled for up to 9 hours.
For the periods when you are away you can use the Holiday function, which will turn off the relay. The Holiday Mode can be set for a period of maximum 31 days.
When connected to a system with a non-programmable (digital) thermostat, it can turn the boiler ON or OFF and control the heating and/or hot water in your system in a programmed manner.
The heating system and the hot water will be controlled with the EP210, meaning that this will send the command of turning the relay on or off when needed, according to the programs created. The EP210 programmable controller does not detect or adjust the temperature in your house, it is just sending the commands to the boiler, motorized valve or thermostat to turn ON or OFF the relay, depending on the program settings.
The programs can be set individually for each channel, or, you can program them together if you want your heating and hot water to be controlled in a coordinated manner.

Product Compliance
This product complies with the essential requirements and other relevant provisions of the following EU Directives: 2014/30/EU, 2014/35/EU and 2011/65/EU. Please check www.saluslegal.com for the full information.

Safety Information
Use in accordance with the EU and national regulations. For indoor use only. Keep your device completely dry. This product must be installed by a competent person and in accordance with all the EU and national regulations.
Always isolate the AC Mains supply before installing or working on any components that require 230 VAC 50Hz supply.

Box content

The box includes the EP210 controller, 2X screws and plugs and the Quick Guide installation manual. SALUS EP210 Dual channel programmable Thermostat product fig-1

Features

  • Dual Channel Programmer for Central Heater or Hot Water
  • 12 or 24-hour clock format
  • 5+2 or 24 h individual programs with 3 settings per day
  • Boost function
  • Holiday function
  • Advance function
  • Memory backup

Installation

Wiring and terminal descriptionSALUS EP210 Dual channel programmable Thermostat product fig-2

Wall mounting

SALUS EP210 Dual channel programmable Thermostat product fig-3

Jumper settings
The jumpers are found on the rear of your controller and can be used to change the settings for the: program type, system type (fully pumped and controlled or gravity-fed) and internal backup memory battery. If you want to change the position of the jumpers, please note that you will need to reset your device.SALUS EP210 Dual channel programmable Thermostat product fig-4

SALUS EP210 Dual channel programmable Thermostat product fig-5

Note: Changes to the jumper setting should only be made by the engineer carrying out the installation or another qualified person. The installer should select the jumper positions required if changes need to be made to the factory default settings. These jumpers are found on the rear of the controller.

Button functions

SALUS EP210 Dual channel programmable Thermostat product fig-6

Key Function
SALUS EP210 Dual channel programmable Thermostat product fig-7Mode Press to select ON/ONCE/AUTO/ADV/OFF for hot water
SALUS EP210 Dual channel programmable Thermostat product fig-8 Mode Press to select ON/ONCE/AUTO/ADV/OFF for heating
+Hr Press to enter/cancel Boost override function by setting Boost hours.
Select Press to select the setting of clock/date/week day, etc.
Set Press to confirm the setting.
Up arrow Press to increase clock/day, press and hold to enter fast advance.
Down arrow Press to decrease clock/day, and press and hold to enter fast advance.
SALUS EP210 Dual channel programmable Thermostat product fig-9 Press to activate the backlight.
SALUS EP210 Dual channel programmable Thermostat product fig-10 Hardware reset
SALUS EP210 Dual channel programmable Thermostat product fig-34 Press and hold the button for 3 seconds to activate Holiday mode.
Select + Set Press and hold buttons to enter clock setting mode.

LCD icons

SALUS EP210 Dual channel programmable Thermostat product fig-12

  1. Days of the week
  2. Clock
  3. Heating zone
  4. Boost hours for heating
  5. Holiday Mode
  6. Boost hours for hot water
  7. AM/PM
  8. Hot Water On
  9. OFF Mode
  10. ADV Mode On
  11. AUTO Mode
  12. On ONCE Mode
  13. On On Mode
  14. DST On/Off
  15. Program number

Operations

Initial power up
After power up or after RESET is pressed, the programmer is reset to factory default settings. During system reset, all LCD icons and segments are turned on for 2 seconds and all keys are blocked. After 2 seconds and all keys are released, the programmer is initialized. First the software version is shown and after that the typical reset display is shown. The time should be 12:00am.SALUS EP210 Dual channel programmable Thermostat product fig-13

Default settings

Function Status after Reset
Operation Mode Normal mode
Clock 12:00 AM
AM/PM indicator AM
Date January 1, 2016
Daylight Saving Time(DST) On
Program Factory default 5+2
Program Number indicator Off
SET indicator Off
PROG indicator Off
Mode indicator(s) “Off“
Output Relay Off
CH/HW indicator(s) Off

Setting time and date
The first thing you will have to do is to set the time and date on your controller. First you will need to set up the time and then the date. To enter clock setting mode, press and hold Select and Set buttons for 3 seconds. Please follow the instructions below.SALUS EP210 Dual channel programmable Thermostat product fig-14SALUS EP210 Dual channel programmable Thermostat product fig-15

When Daylight saving time is enabled, the clock will automatically change from Greenwich Mean Time (GMT) to British Summer Time (BST) on the last Sunday in March. The clock will automatically change back to GMT on the last Sunday in October.

Operating Modes
EP210 can operate in 5 different modes, applicable to the CH, HW or CH+HW. The operation modes are the same for CH and HW and can be set individually, or together. If you want to choose the mode for the CH, press theSALUS EP210 Dual channel programmable Thermostat product fig-7 Mode key. If you want to choose the mode for the HW, press the SALUS EP210 Dual channel programmable Thermostat product fig-8Mode Key.

Operation Mode Function
ON Continuously on
ONCE On for 1 period a day, from Program 1 ON to Program 3 OFF
AUTO Automatic program control
 

ADV

When device is in Auto or Once mode, press the MODE button for 3 sec for selecting Advance (ADV). This will move the unit into the next program. When the ADV function ends the device will return to normal program.
OFF Continuously off

For activating the functions described above, press the MODE button. The operating mode is cycled in the below sequence:SALUS EP210 Dual channel programmable Thermostat product fig-16

ON ModeSALUS EP210 Dual channel programmable Thermostat product fig-17

Pressing the Mode key once activates the ON Mode. In ON mode, the controller gives the boiler the ON command, so the heating or/and hot water will run continuously.SALUS EP210 Dual channel programmable Thermostat product fig-18

Pressing the Mode key twice activate the ONCE Mode. In ONCE mode, the controller gives the boiler the command to run only for one period per day (from program 1 ON to program 3 OFF)SALUS EP210 Dual channel programmable Thermostat product fig-19

Pressing the Mode key 3 times activates the AUTO. In AUTO mode, the controller gives the boiler the ON/OFF command depending on your schedule.

OFF ModeSALUS EP210 Dual channel programmable Thermostat product fig-20

Pressing the Mode key 4 times activates the OFF Mode. In OFF mode, the controller gives the boiler the OFF command, so the heating or the hot water will be turned off.

ADV Mode
Note: In ONCE or AUTO mode, by long pressing the MODE button, the controller will switch automatically to ADV. You can cancel the ADV by long-pressing the MODE key. The device will then return to ONCE or AUTO mode. You can’t select ADV by pressing Mode key SALUS EP210 Dual channel programmable Thermostat product fig-21

When in Auto mode selecting ADV, the controller will simply toggle the current auto setting (ON or OFF). For example, if the current program is set as:SALUS EP210 Dual channel programmable Thermostat product fig-22

Selecting ADV between 8:00 and 8:59 will change the output to OFF, from 9:00 onwards back to AUTO (which is also OFF). Selecting ADV between 9:00 and 09:59 will change the output to ON, from 10:00 onwards back to AUTO (which is also ON). If the ADV puts the relay ON then the boost would apply immediately at the next OFF change, if the ADV put the relay OFF then the boost would apply immediately and turn the relay ON.SALUS EP210 Dual channel programmable Thermostat product fig-23

If ADV occurs at 08:30 and the relay is ON from 08:30 to 12:00. During this period, if at 08:45 +1Hr (Boost) is pressed, the relay will be ON from 08:30 to 12:00. Boost is applied immediately ie. from 08:45 to 09:45 at the next change, ie. 12:00. If ADV occurred at 10:30 the relay will be ON from 10:00, OFF from 10:30 (ADV) to 14:00 if no +1Hr Override. During ADV, if at 10:45 +1Hr (Boost) is pressed, the relay will go ON again at 10:45 (boost starts), OFF at 11:45 (Boost ends) until ends at 14:00, then ON again at 14:00.

Programming the EP210
2 types of programs can be set:

  • 5+2 (Mon to Fri same and Sat, Sun same)
  • Different programs for each 24h.
    There are 3 different time sets for each day.
5-2 Days Program Individual Days Program
Weekdays

3 sets of time/channel Weekends

3 sets of time/channel

Total: 12 settings/week

1 Day

3 sets of time/channel

 

 

Total: 42 settings/week

EP210 is a dual-channel controller, that gives the possibility to control both Central Heating and Hot Water. You can choose which one you would like to control, by simply pressingSALUS EP210 Dual channel programmable Thermostat product fig-7 the Mode key for Central HeatingSALUS EP210 Dual channel programmable Thermostat product fig-8 or the Mode key for hot Water, or you can use both. You can program the schedules for these outputs individually or together. When you program them together, there will be the same program time for both Heating and Hot Water. If you choose to program them individually, you can have different program times for each.
5+2 Program

Programing CH and HW individuallySALUS EP210 Dual channel programmable Thermostat product fig-25

Please continue by following the same steps for programs nr 2 and 3. After you finish programming CH for weekdays, the controller will ask you to do the same thing for the Hot Water. You can choose a different or similar end/start time. The LCD will look like step 12.

The sequences followed by the controller when programming CH and HW individually go at it follows:

  • Weekday CH (program 1-3) Weekday HW (program 1-3)
  • Weekend CH (program 1-3) Weekend HW (program 1-3) and all over again. SALUS EP210 Dual channel programmable Thermostat product fig-26

Note: To save your settings and exist to home screen in normal mode, press Set at any time.

Programming CH and HW together
The programming principle is exactly the same, but you can only set the same Start/End time for the CH and HW. The programming sequence goes as it follows: Weekday CH+HW Weekend CH+HW and all over again. To program them together, follow the steps:SALUS EP210 Dual channel programmable Thermostat product fig-27 Setting different programs for each 24h
Note: Don’t forget to move the jumpers to 24h in order to have the individual program active. After that please follow the same instructions as for the 5-2 days program.

Programming CH and HW individuallySALUS EP210 Dual channel programmable Thermostat product fig-28

Please continue by following the same steps for programs nr 2 and 3. After you finish programming CH for Monday, the controller will ask you to do the same thing for the Hot Water. You can choose a different or similar end/start time. The LCD will look like step 12.SALUS EP210 Dual channel programmable Thermostat product fig-29

The sequences followed by the controller when programming CH and HW individually go at it follows:

  • Monday CH (program 1-3) Monday HW (program 1-3)
  • Tuesday CH (program 1-3) Tuesday HW (program 1-3)
  • Wednesday CH (program 1-3) Wednesday HW (program 1-3) etc

Note: To save your settings and exist to home screen in normal mode, press Set at any time.

Programming CH and HW together 
The programming principle is exactly the same, but you can only set the same Start/End time for the CH and HW. The programming sequence goes as it follows: Monday CH+HW Tuesday CH+HW Wednesday
CH+HW etc.
To program them together, follow the steps:SALUS EP210 Dual channel programmable Thermostat product fig-30

Functions

Temporary Override
Boost Override (+1Hr override)
Boost Override (+1Hr override) is available in ONCE/AUTO/OFF modes. Boost mode can be activated even in ADV mode. When boost mode is activated, ADV is canceled. Press +1Hr at current mode to activate the Boost Override (+1Hr override) setting mode. Boost mode increases the time of the active program by 1-9 hours. The new setting hour “+x” (x=last boost hour+1 hour) is displayed. Subsequent press of +1Hr will increase the duration by 1 hour. Maximum duration is 9 hours. If the number rolls back to blank, this will disable the Boost Override.
Boost Override (+1Hr override) for HeatingSALUS EP210 Dual channel programmable Thermostat product fig-31

Boost Override (+1Hr override) can be available for CH and HW at the same time.

ADV Override
ADV only works in AUTO or ONCE mode. During ADV, press MODE once to cancel ADV and go back to AUTO /ONCE mode after LCD backlight is turned off.
+1Hr override and ADV cannot co-exist in same channel. During ADV mode, when +1Hr is pressed, override mode will cancel ADV mode then change to Boost mode. If +1Hr override (Boost) is running, then ADV is selected, ADV will be activated and the previous +1Hr override will be canceled.

ADV Override for HeatingSALUS EP210 Dual channel programmable Thermostat product fig-32

 

ADV Override for Hot Water SALUS EP210 Dual channel programmable Thermostat product fig-33

Holiday Override
During the period of holiday override, relay should be always Off.
Press and holdSALUS EP210 Dual channel programmable Thermostat product fig-34 at current mode for 3 seconds to activate the Holiday Override setting mode. The plane icon will be displayed on the LCD and the user’s only option will be to set the number of holiday days (up to 31). To exit Holiday Override and turn On the relay, long pressSALUS EP210 Dual channel programmable Thermostat product fig-34 the key.SALUS EP210 Dual channel programmable Thermostat product fig-35

LCD Backlight
If AC is powered, LCD backlight is activated when or any key is pressed. The backlight will be turned off in 15 seconds after all keys are released.

Factory Reset

If you want to return to the factory settings please press the Reset button once (use a pin for this action).SALUS EP210 Dual channel programmable Thermostat product fig-36

Technical Info

Product Specification
Model: EP210
Type: Surface Mounted Wired Dual Channel Programmable Timer
Memory Backup Lithium battery (CR2032 x1pc)
Power control
Rating 230V/50Hz/3(1)A
Relay SPDT
Protection Rating: IP 30
Environment
Operating Temperature/ Humidity: 0°C ~ 50°C, 10% – 90% non-condensing
Storage Temperature/ Humidity -20°C~- 60°C, 10% – 90% non-condensing
Programs
Program 5-2 or 24hr individual program (selectable by jumper), 3 settings/day, with holiday override.
Boost Override Yes, max 9 hours(selectable by software)
Holiday Override Yes, max 31 days (selectable by software)
Clock
Clock Format 12 or 24 hour (selectable by software)
Clock Accuracy +/-1 min/month
Daylight Saving Time (DST) Yes, Clock is automatically adjusted if DST is enabled.

Warranty

SALUS Controls warrants that this product will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of two years from the date of installation. SALUS Controls’ sole liability for breach of this warranty will be (at its option) to repair or replace the defective product.

  • Customer Name: ….
  • Customer Address: ….
  • Tel No: ….. Email: ….
  • Company Name: …..
  • Tel No: …….. Email: …
  • Installation Date: ……
  • Installer Name: …..
  • Installer Signature: ……..

SALUS Controls PlcUnits 8-10 Northfield Business ParkForge Way, Parkgate, RotherhamS60 1SD, United Kingdom
Sales: T: +44 (0) 1226 323961
E: sales@salus-tech.com
Technical: T: +44 (0) 1226 323961
E: tech@salus-tech.com

SALUS Controls is a member of the Computime Group
Maintaining a policy of continuous product development, SALUS Controls plc reserves the right to change the specifications, design and materials of products listed in this brochure without prior notice.
For the latest PFD Instruction Manual, go to www.salus-manuals.com 

 

SALUS logo

SALUS EP210 Dual channel programmable Thermostat Installation Manual

The post SALUS EP210 Dual channel programmable Thermostat Installation Manual appeared first on thermostat.guide.



source https://thermostat.guide/salus/salus-ep210-dual-channel-programmable-thermostat-installation-manual/

No comments:

Post a Comment

Blyss Valkla Digital Thermostat User Manual

Blyss Valkla Digital Thermostat What is in the box Check the contents of the packaging and the visual condition of the products. Contents of...